Cavity Wall Insulation - Premier Insulations

Foam Fill - Existing House - No Insulation

Foam fill cavity wall insulation

The best solution

Although there are many cheaper options on the market, FOAMFILL is the most effective way to dramatically reduce heat loss through external walls. The foam which resembles a shaving foam is injected through small (16mm) pre drilled holes under 120 Ibs of pressure. The foam completely fills the cavity and later solidifies creating a solid mass of insulation within the cavity. With the exception of new build, all the work takes place from the outside and most installations are completed within a day.

wrap up this winter
with FOAMFILL
wrap up this winter with FOAMFILL

Why Foamfill

FOAMFILL insulation is self supporting and will not settle or sag within the cavity to create voids. FOAMFILL will not absorb water and has excellent fire resistance. Unlike other insulation products, Foamfill has no effect on electrical cables or wall ties and is not effected by frost. It is rot and decay proof and requires no maintenance.

 

BEST U-VALUES

  Width/W/mc Thermal Resistance
External Surface
Render
Outer Block (5% me)
Fractional area 0.828
Outer mortar
Fractional area 0.172
CaVity u/foamed
Inner Block (3% me)
Fractional area 0.934
Inner mortar
Fraclional area 0.066
Plasterboard
Internal Surlace
-
25mml1.0
100mm/0.26
-
100mm/0.9
-
l00mm/O.04
100mm/0.16
-
loomm/0.8
-
9.5mm/0.16
-
0.053
0.025
0.319
-
0.0196
-
2.50
0.584
-
0.00825
-
0.59
0.12
  Total: 4.219
U-Value becomes 1 divided by 4.219=0.237
  U-Value .24

Whilst the installation of any cavity wall insulation will reduce heat loss and improve the thermal efficiency of the walls, none can compare with FOAMFILL A U-Value of .24 is easily achieved in a standard cavity compared with .34 using white polystyrene beads. A whopping 40% more efficient.

Foamfill cavity wall insulation

 

Quality Assurance

The quality assurance systems of the materials for foamfill insulation are approved under BS EN ISO.9000. The quality of Foamfill is specified and controlled in accordance with BS 5617. The system is installed in compliance with procedures as laid down DIN BS 5618

Our Guarantee to you!

Each installation comes with a 5 year guarantee.

 

Foamfill when only the best will do

 
 