Cavity Wall Insulation - Premier Insulations

Foam Fill - House under Construction - Some Insulation

 
Foam fill cavity wall insulation
 

The best solution

Cavity wall with 60mm board already
fitted

Picture illustrates existing board fitted
in cavity (yellow) and topped up with
'Foamfill' (white)

Insulation board is usually installed to a thickness of 60mm in a 105mm cavity, assuming the board is correctly installed the current required u-value of .027 w/m2/K is achieved.

To improve the thermal effiency of the wall the board can be topped up with Foamfill As the foam is injected under 130 lbs pressure, it will fill any voids left between the boards or any areas where the board is poorly fitted.

 

 

holes being drilled in New House Foam being injected in a New House

Why Foamfill

FOAMFILL insulation is self supporting and will not settle or sag within the cavity to create voids. FOAMFILL will not absorb water and has excellent fire resistance. Unlike other insulation products, FoamFill has no effect on electrical cables or wall ties and is not effected by frost. It is rot and decay proof and requires no maintenance.

  Width/W/mc Thermal Resistance
External Surface
Render
Outer Block (5% me)
Fractional area 0.828
Outer mortar
Fractional area 0.172
CaVity u/foamed
Inner Block (3% me)
Fractional area 0.934
Inner mortar
Fractional area 0.066
Plasterboard
Internal Surface
-
25mml1.0
100mm/0.26
-
100mm/0.9
-
l00mm/O.04
100mm/0.16
-
100 mm/0.8
-
9.5mm/0.16
-
0.053
0.025
0.319
-
0.0196
-
2.50
0.584
-
0.00825
-
0.59
0.12
  Total: 4.219
U-Value becomes 1 divided by 4.219=0.237
  U-Value .24

BEST U-VALUES

Whilst the installation of any cavity wall insulation will reduce heat loss and improve the thermal efficiency of the walls, none can compare with FOAMFILL A U-Value of .24 is easily achieved in a normal 100mm cavity compared with .34 using white polystyrene beads. A whopping 40% more efficient.

Quality Assurance

The quality assurance systems of the materials for foamfill insulation are approved under BS EN ISO.9000. The quality of Foamfill is specified and controlled in accordance with BS 5617. The system is installed in compliance with procedures as laid down DIN BS 5618

Our Guarantee to you!

Each installation comes with a 5 year guarantee.

 

Foamfill when only the best will do

 
fOAMFILL OUTPERFORMS ALL OTHER INSULATION SSYTEMS
 
Click here to Back to the last page
How to Contact Us?
Insulation Home | Cavity Wall Insulation | Hollow Block Insulation | Attic Insulation | Foam Spray/ Airtightness | Industrial Spraying | Company History | Why Insulate | Testimonials | Links | Grants | FAQ | Certs
© 2007   Premier Insulations - All rights reserved
Email: info@premierinsulations.com     Web: www.premierinsulations.com
Freephone: 1800 64 64 10